• Skip to primary navigation
  • Skip to main content
Cimarron Energy. Creating a cleaner environment.
  • About Us
  • Leadership
  • ESG
  • Careers
  • Blogs/News
  • Library
  • Contact Us
    • SYTELINK360® – REAL TIME PERFORMANCE MONITORING
    • ARC® Burner Management System
    • NEW DRE-Max® II – Smart Control for Gas-Assisted Flares
    • NOVENT® – Smart Thief Hatch Monitoring
    • Opti Link® – Alerts and Continuous Monitoring
    • EMISSIONS MANAGEMENT SOLUTIONS
    • Emissions Detection and Control
    • Smart Vapor Recovery Systems
    • Smart Enclosed Combustors
    • Smart Flare Systems
    • BTEX Elimination Systems
    • PRODUCTION & PROCESSING EQUIPMENT
    • Oil and Gas Production Equipment
    • Gas Processing Systems
    • Modular Facilities
    • Plungers & Prime Movers
  • AFTERMARKET PARTS & FIELD SERVICES
  • Aftermarket Parts & Services
  • Refurbishing & Upgrading Equipment Services
  • Rental Equipment

Copyright © Cimarron Energy, Inc. All Rights Reserved

Smart Enclosed Combustors

10 EPA certified – 14 standard models

A battery of 48″ High Volume EPA certified combustors.

A battery of 48″ High Volume EPA certified combustors

With the rapid growth of oil and gas production in the North American shale plays and other areas, Cimarron has answered the call with a series of OOOOb/c certified or compliant standard Smart Combustors that deliver the high performance and rapid delivery you need at very economical price points.

All our standard Smart Enclosed Combustors come with the integrated continuous monitoring Optilink™ module and a burner management system, ensuring compliance with the new OOOOb/c regulations. They are easy to install and require little ongoing maintenance.

In addition, our 10 EPA certified combustor models have been demonstrated to have >99% destruction efficiency based on NSPS OOOOa/b/c performance testing, in a controlled environment. This is why we are guaranteeing 98% in any well site environment when used within their recommended range.

 

We offer 3 types of combustor designs, each with different price points and different strengths:

The AB design

The AB enclosed combustors are an excellent solution for applications that require ease of transportation, and a small footprint. These combustors have low pressure drop burners, are made entirely of stainless steel, are not insulated and do not have flame cells. Because of this, customers should control the access and delicate equipment near the units due to the radiating heat while in operation. They come with integrated continuous monitoring.

The CH design

The CH units are also are an excellent solution for applications that require ease of transportation and a small footprint. These combustors have low pressure drop burners and are internally insulated with ceramic, which makes them a better choice when temperature is high and varies widely. However these units do not have any flame cells and customers should control the access to the equipment when in operation. They come with integrated continuous monitoring.

The CIMARRON design

The Cimarron enclosed combustors have the best turndown ratio on the market because of their special multijets burner design which also provides better smokeless performance. The larger units are insulated with fiberglass, with little heat radiating from them. These units are very versatile and can be upgraded to be temperature controlled with gas-assist (truck loading, BTEX, low vapors applications). The Ultra High Volume units are not EPA certified due to their size, but have been field tested to be well above 98% DRE. They come with integrated continuous monitoring.

 

 

Request a Smart Enclosed Combustor Design Datasheet

 

 

Select a model below based on max flow rate (in MSCFD)

CEI-1-24

  • Model: CEI-1-24
  • EPA certified: Yes (8/12/2014)
  • Max Flow Rate: 9.2 MSCFD @ 10 oz/in using SG 1.0/1700 BTU/SCF
  • Min Flow Rate: 2.0 MSCFD
  • Max Heat Release: 0.98 MMBtu/hr
  • Inlet Pressure Range: 1 to 16 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 30 SCFH @ 8-10 psig (per ignitor)
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 4.5 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 24″ OD x 8.3′ high
  • Brand: Cimarron

CEI-1-30

  • Model: CEI-1-30
  • EPA certified: Yes (8/12/2014)
  • Max Flow Rate: 15.0 MSCFD
  • Min Flow Rate: 3.1 MSCFD
  • Max Heat Release: 1.6 MMBtu/hr
  • Inlet Pressure Range: 1 to 16 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 14-17 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 5 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 30″ OD x 8.3′ high
  • Brand: Cimarron

3 models: CEI-1-48 | Abutec 20 | HY-BON CH2.5

  • Model 1: CEI-1-48
  • EPA certified: Yes (8/12/2014)
  • Max Flow Rate: 30.0 MSCFD
  • Min Flow Rate: 4.8 MSCFD
  • Max Heat Release: 3.2 MMBtu/hr
  • Inlet Pressure Range: 1 to 16 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 14-17 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 6 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 48″ OD x 11.6′ high
  • Brand: Cimarron

Model 2: AB20

  • EPA certified: Yes (2/12/2013)
  • Max Flow Rate: 36.0 MSCFD
  • Min Flow Rate: 8.0 MSCFD
  • Max Heat Release: 2.5 MMBtu/hr
  • Inlet Pressure Range: 3 to 16 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 14-17 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 4.5 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 34″ OD x 192″ high
  • Brand: Abutec

Model 3: CH2.5

  • EPA certified: Yes (9/16/2015)
  • Max Flow Rate: 36.0 MSCFD
  • Min Flow Rate: 8.0 MSCFD
  • Max Heat Release: 2.5 MMBtu/hr
  • Inlet Pressure Range: 1 to 10 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 14-17 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 4.5 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 34″ OD x 192″ high
  • Brand: HY-BON/EDI

Model: CEI-1-60

  • EPA certified: Yes (8/12/2014)
  • Max Flow Rate: 57.6 MSCFD
  • Min Flow Rate: 12.0 MSCFD
  • Max Heat Release: 6.1 MMBtu/hr
  • Inlet Pressure Range: 1 to 16 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 14-17 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 4.8 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 60″OD x 13.4′ high
  • Brand: Cimarron

2 models: 48″ HV ECD | HY-BON CH 10.0

  • Model 1: 48” HV ECD
  • EPA certified: Yes (8/12/2014)
  • Max Flow Rate: 109.0 MSCFD
  • Min Flow Rate: 13.7 MSCFD
  • Max Heat Release: 11.7 MMBtu/hr
  • Inlet Pressure Range: 1 to 16 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 14-17 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 8 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 56″ square base x 25′ high
  • Brand: Cimarron

Model 2: CH10.0

  • EPA certified: Yes (6/16/2015)
  • Max Flow Rate: 100.1 MSCFD
  • Min Flow Rate: 34.0 MSCFD
  • Max Heat Release: 10.0 MMBtu/hr
  • Inlet Pressure Range: 1 to 10 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 14-17 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 3 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 54″ OD x 240″ high
  • Brand: HY-BON/EDI

Abutec 100

  • Model: AB100
  • EPA certified: Yes (2/12/2013)
  • Max Flow Rate: 144.0 MSCFD
  • Min Flow Rate: 30.0 MSCFD
  • Max Heat Release: 9.2 MMBtu/hr
  • Inlet Pressure Range: 3 to 16 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 14-17 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 5 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 30″ OD x 16.3′ high
  • Brand: Abutec

2 models: Abutec 200 | 60″ HV ECD

Abutec 200

  • Model: AB200
  • EPA certified: Yes (2/12/2013)
  • Max Flow Rate: 195.8 MSCFD
  • Min Flow Rate: 40.0 MSCFD
  • Max Heat Release: 18.4 MMBtu/hr
  • Inlet Pressure Range: 3 to 16 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 14-17 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 5 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 47″ OD x 20′ high
  • Brand: Abutec

60″ HV ECD

  • Model: 60” HV ECD
  • EPA certified: No
  • Max Flow Rate: 200.0 MSCFD
  • Min Flow Rate: 30.0 MSCFD
  • Max Heat Release: 30.8 MMBtu/hr
  • Inlet Pressure Range: 1 to 16 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 8-10 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 7 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 68.5″ square base x 26′ high
  • Brand: Cimarron

72″ HV ECD

  • Model: 72” HV ECD
  • EPA certified: No
  • Max Flow Rate: 320.0 MSCFD
  • Min Flow Rate: 32.0 MSCFD
  • Max Heat Release: 31.3 MMBtu/hr
  • Inlet Pressure Range: 1 to 16 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 14-17 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 10 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 72″ square base x 30′ high
  • Brand: Cimarron

84″ HV ECD

  • Model: 84” HV ECD
  • EPA certified: No
  • Max Flow Rate: 550.0 MSCFD
  • Min Flow Rate: 55.0 MSCFD
  • Max Heat Release: 53 MMBtu/hr
  • Inlet Pressure Range: 1 to 16 oz/in2
  • Pilot fuel required: 5-7 psig
  • Pilot fuel consumption: 14-17 SCFH
  • Stack Temperature: 500-1200 Deg F
  • Turndown ratio: 10 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 84″ square base x 32′ high
  • Brand: Cimarron

96″ HV ECD

  • Model: 96” HV ECD
  • EPA certified: No
  • Max Flow Rate: 625.0 MSCFD
  • Min Flow Rate: 100.0 MSCFD
  • Max Heat Release: 65 MMBtu/hr
  • Inlet Pressure Range: 1 to 16 oz/in2
  • Pilot fuel required: 8-10 psig
  • Pilot fuel consumption: 120 SCFH
  • Stack Temperature: 1400 Deg F
  • Turndown ratio: 6 : 1
  • VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
  • Dimensions: 96″ square base x 40′ high
  • Brand: Cimarron

Ready for real results?

Contact Us
    • 12120 Wickchester Ln Suite 400
      Houston, TX 77079
    • 1 (844) 746-1676
Products
    • Smart Vapor Recovery Systems
    • Smart Enclosed Combustors
    • Smart Flare Systems
    • Oil and Gas Production Equipment
    • Gas Processing Systems
    • Plungers & Prime Movers
Services
    • Aftermarket Services
    • Refurbishing & Upgrading
    • Rental Equipment
Technologies
    • Emissions Solutions
    • Sytelink360®
    • ARC®
    • DRE-Max®
    • NOVENT®
Resources
    • Blogs/News
    • Careers
    • About Us
    • Contact Us

Cimarron Energy, INC. is a member of ISNetworld. ISN provides compliance services and keeps records of all of our safety plans.

Privacy Policy | © 2025 Cimarron Energy, Inc. All rights reserved.

Houston, TX | Evans, Co Indiana, PA | Marlow, OK | Norman, OK | Midland, TX | Wheat Ridge, Col Wichita Falls, TX

Download Sustainability Report

Please enter your  information in order to download our 2021 Sustainability Report.

"*" indicates required fields

Name*
This field is for validation purposes and should be left unchanged.
Request a Design Datasheet

Enter your contact information in order to receive the design datasheet

"*" indicates required fields

Name*
This field is for validation purposes and should be left unchanged.