Automatic ignition and pilot flame data logging on flare systems, making flares OOOOa compliant
High capacity / small footprint portable combustors
Compliance documentation for operators
Automated BTEX condenser with EPA certified combustor for dehydration units – compliance solution for dehy still column overheads
Example 1 VOC Emissions – Truck Loading
PROBLEM Customer needed to achieve 98% reduction in vapor emissions from the site, but truck loading was problematic
SOLUTION • Customized firmware • Utilize existing (standard) equipment
VALUE • Use of existing equipment – lower CAPEX • Minimized assist gas = lower LOE
Example 2 Managing Multiple Fired Units
- Multiple units can be fired and managed with one BMS controller
- Can manage up to 16 fired vessels with one controller and individual ignition coils
Example
- Control eight fired units with auto ignition, fuel valve and temperature control – C1D2 + Modbus RS485
- > 30% savings compared to using individual controllers