Cimarron’s Enclosed Combustors (ECDs) have a demonstrated field destruction efficiency greater than 98% DRE when used within the recommended specs. Designed for both low and high volume applications, they are easy to install and require little ongoing maintenance.
In addition, EPA certified combustors have been demonstrated to have >99% destruction efficiency based on NSPS OOOO/OOOOa performance testing, in a controlled environment.
Ignition System
By default, the Cimarron combustors all are controlled by an ARControl™ ignition system that includes, but is not limited to:
- Auto-reignition with pilot flame sensing
- Automation capability
- data logging
- performance sustainability features for records and reporting.
- Option to operate 2 combustors, or combustors/1 flare, or 1 combustor/1 heater treater with a single ARControl™ module when used in Dual BMS mode.
- Optional continuous performance monitoring system (Sytelink) to optimize the equipment uptime.
10 EPA certified – 12 standard models
Additional Ultra-High Volume models available
Select a model below based on max flow rate (in MSCFD)
Warning: max available flow rates were data points measured in a controlled environment.
Actual gas composition, inlet pressure, and expected flow rate are necessary to properly size a combustors capacity for any given application.

CEI-1-24
- Model: CEI-1-24
- EPA certified: Yes (8/12/2014)
- Max Flow Rate: 9.2 MSCFD @ 10 oz/in using SG 1.0/1700 BTU/SCF
- Min Flow Rate: 2.0 MSCFD
- Max Heat Release: 0.98 MMBtu/hr
- Inlet Pressure Range: 1 to 16 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 30 SCFH @ 8-10 psig (per ignitor)
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 4.5 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 24″ OD x 8.3′ high
- Brand: Cimarron

CEI-1-30
- Model: CEI-1-30
- EPA certified: Yes (8/12/2014)
- Max Flow Rate: 15.0 MSCFD
- Min Flow Rate: 3.1 MSCFD
- Max Heat Release: 1.6 MMBtu/hr
- Inlet Pressure Range: 1 to 16 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 14-17 SCFH
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 5 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 30″ OD x 8.3′ high
- Brand: Cimarron

3 models: CEI-1-48 | Abutec 20 | HY-BON CH2.5
- Model 1: CEI-1-48
- EPA certified: Yes (8/12/2014)
- Max Flow Rate: 30.0 MSCFD
- Min Flow Rate: 4.8 MSCFD
- Max Heat Release: 3.2 MMBtu/hr
- Inlet Pressure Range: 1 to 16 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 14-17 SCFH
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 6 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 48″ OD x 11.6′ high
- Brand: Cimarron
Model 2: AB20
- EPA certified: Yes (2/12/2013)
- Max Flow Rate: 36.0 MSCFD
- Min Flow Rate: 8.0 MSCFD
- Max Heat Release: 2.5 MMBtu/hr
- Inlet Pressure Range: 3 to 16 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 14-17 SCFH
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 4.5 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 34″ OD x 192″ high
- Brand: Abutec
Model 3: CH2.5
- EPA certified: Yes (9/16/2015)
- Max Flow Rate: 36.0 MSCFD
- Min Flow Rate: 8.0 MSCFD
- Max Heat Release: 2.5 MMBtu/hr
- Inlet Pressure Range: 1 to 10 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 14-17 SCFH
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 4.5 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 34″ OD x 192″ high
- Brand: HY-BON/EDI

Model: CEI-1-60
- EPA certified: Yes (8/12/2014)
- Max Flow Rate: 57.6 MSCFD
- Min Flow Rate: 12.0 MSCFD
- Max Heat Release: 6.1 MMBtu/hr
- Inlet Pressure Range: 1 to 16 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 14-17 SCFH
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 4.8 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 60″OD x 13.4′ high
- Brand: Cimarron

2 models: 48″ HV ECD | HY-BON CH 10.0
- Model 1: 48” HV ECD
- EPA certified: Yes (8/12/2014)
- Max Flow Rate: 109.0 MSCFD
- Min Flow Rate: 13.7 MSCFD
- Max Heat Release: 11.7 MMBtu/hr
- Inlet Pressure Range: 1 to 16 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 14-17 SCFH
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 8 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 56″ square base x 25′ high
- Brand: Cimarron
Model 2: CH10.0
- EPA certified: Yes (6/16/2015)
- Max Flow Rate: 100.1 MSCFD
- Min Flow Rate: 34.0 MSCFD
- Max Heat Release: 10.0 MMBtu/hr
- Inlet Pressure Range: 1 to 10 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 14-17 SCFH
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 3 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 54″ OD x 240″ high
- Brand: HY-BON/EDI

Abutec 100
- Model: AB100
- EPA certified: Yes (2/12/2013)
- Max Flow Rate: 144.0 MSCFD
- Min Flow Rate: 30.0 MSCFD
- Max Heat Release: 9.2 MMBtu/hr
- Inlet Pressure Range: 3 to 16 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 14-17 SCFH
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 5 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 30″ OD x 16.3′ high
- Brand: Abutec

Abutec 200
- Model: AB200
- EPA certified: Yes (2/12/2013)
- Max Flow Rate: 195.8 MSCFD
- Min Flow Rate: 40.0 MSCFD
- Max Heat Release: 18.4 MMBtu/hr
- Inlet Pressure Range: 3 to 16 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 14-17 SCFH
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 5 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 47″ OD x 20′ high
- Brand: Abutec

72″ HV ECD
- Model: 72” HV ECD
- EPA certified: No
- Max Flow Rate: 320.0 MSCFD
- Min Flow Rate: 32.0 MSCFD
- Max Heat Release: 31.3 MMBtu/hr
- Inlet Pressure Range: 1 to 16 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 14-17 SCFH
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 10 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 72″ square base x 30′ high
- Brand: Cimarron

84″ HV ECD
- Model: 84” HV ECD
- EPA certified: No
- Max Flow Rate: 550.0 MSCFD
- Min Flow Rate: 55.0 MSCFD
- Max Heat Release: 53 MMBtu/hr
- Inlet Pressure Range: 1 to 16 oz/in2
- Pilot fuel required: 5-7 psig
- Pilot fuel consumption: 14-17 SCFH
- Stack Temperature: 500-1200 Deg F
- Turndown ratio: 10 : 1
- VOC destruction efficiency: Min. 95 DRE (98 DRE Avail.)
- Dimensions: 84″ square base x 32′ high
- Brand: Cimarron